• Adaptation of the bottle finishes using the Steinfurth Universal PET Holder Set
Saiba Mais:
Flow Through Spout Tester for sport closures.
The Spout Flow Meter is a means for comparing (and measuring) the flow of resistance in “sport closures”.
Operation:
• As a parameter for flow properties, the standardized test includes the use of the Spout Flow Meter yields,
• The time needed for the free outflow is 1 liter of water from a vertically mounted plastic pipe with an internal diameter of 74 mm through the sport closure (spout down) with a minimum water level of 150 mm above the bottom end of the closed spout.
• Flow time is measured manually, using a stop watch
• Metrics: Flow Rate
• Property: Sports closures
• Features: Standardized test stand for flow measurement
• System: Yes
• Measurement category: Physical Performance Test Method for Sport Closures – Flow Through Spout
• Weight: 7.5 kg
• Dimensions (LxWxH): 250 x 250 x 800mm
• Necessary test items: Spout Flow Meter with sport closure attached Beaker (minimum volume 2000 ml) Stop watch or lab timer